Objective:
To produce 50 polyurethane sets for MRI medical system.
Duration: 4 Weeks
Process:
SLS – prototypes were used as a master to produce
the silicone rubber molds.
Into the silicone rubber molds RIM grade PU material was injected
& prototypes obtained. Average through put was about 5
sets of LH & RH covers each day.
The Component dimension of 800x340x260 mm with gluing of metal
locks to PU parts posted a challenge. Finally the components
were painted before delivering to the customer.
Result: The prototypes were successfully
fitted & the machine was sent for testing to various locations
worldwide.
|